F-Gas Logbook · RG-007

Compliant with F-Gas Reg (EU) 517/2014 retained UK law · Engineer F-Gas certification verified per row

AK
Ali Khan
Tenant admin
Charged (kg, YTD)
4.8
Recovered (kg)
3.2
Leak checks
2
Leaks found
0

All F-Gas events

Statutory record-keeping per Article 6 · Retention 7 years

IDDateEquipmentEventRefrigerantkg ±After (kg)t CO₂eResultEngineer (F-Gas)
RG-007-2026-0122026-05-01
srv-1 / Daikin Altherma 12kW
14 Albert Rd, ST4 1AA
Initial chargeR32+4.54.53.04
James Mosley
FG-9090
RG-007-2026-0112026-04-28
cust-9 / Vaillant aroTHERM
4 Rose Crescent, ST4 7BB
Leak checkR2900.01.40.00No leak
Sarah Patel
FG-9091
RG-007-2026-0102026-04-22
cust-8 / Mitsubishi Ecodan
12 Park Ave, ST4 5DD
Top-upR32+0.34.83.24
James Mosley
FG-9090
RG-007-2026-0092026-04-19
cust-7 / Worcester GS5000
8 King Street, ST4 4FF
Leak checkR454C0.05.20.78No leak
James Mosley
FG-9090
RG-007-2026-0082026-04-15
cust-3 / Daikin Altherma
92 New Lane, ST4 1XX
RecoveryR410A-3.20.06.69
Sarah Patel
FG-9091

Leak-check thresholds

Mandatory annual leak checks where charge ≥ 5 t CO₂-equivalent per F-Gas Reg Article 4. Most domestic ASHPs (3-12 kg R32) sit below the threshold but Anvul performs the check anyway as a reasonable-care + warranty obligation.

< 5 t CO₂e
No statutory check
5 – 50
12-month interval
50 – 500
6-month interval
≥ 500
3-month interval